Get webhook notifications whenever Network & Infrastructure creates an incident, updates an incident, resolves an incident or changes a component status.
On doit installer un SMU sur les ASR9. Il fixe
un bug de port qui passent en \"down\" comme ça
on sait pas pourquoi.
VAC2:
RP/0/RSP0/CPU0:vac2-0-a9(admin)#upgrade hw-module fpd all location 0/0/CPU0
Starting the upgrade/download of following FPD:
=========== ==== ======= ======= =========== =========
Current Upg/Dng
Location Type Subtype Upg/Dng Version Version
=========== ==== ======= ======= =========== =========
0/0/CPU0 lc fpga2 upg 1.17 1.18
------------------------------------------------------
FPD upgrade in progress. Max timeout remaining 89 min.
FPD upgrade in progress. Max timeout remaining 88 min.
FPD upgrade in progress. Max timeout remaining 87 min.
Successfully upgraded fpga2 for ASR9001-LC on location 0/0/CPU0 from 1.17 to 1.18
FPD upgrade has ended.
RP/0/RSP0/CPU0:vac2-0-a9#hw-module location 0/0/CPU0 reload
Fri Oct 11 12:53:44.691 UTC
WARNING: This will take the requested node out of service.
Do you wish to continue?[confirm(y/n)]y
RP/0/RSP0/CPU0:vac2-0-a9#
Update(s):
Date: 2013-10-12 05:09:48 UTC done
Date: 2013-10-12 05:01:54 UTC on attaque le VAC1
Starting the upgrade/download of following FPD:
=========== ==== ======= ======= =========== =========
Current Upg/Dng
Location Type Subtype Upg/Dng Version Version
=========== ==== ======= ======= =========== =========
0/0/CPU0 lc fpga2 upg 1.17 1.18
------------------------------------------------------
FPD upgrade in progress. Max timeout remaining 89 min.
Date: 2013-10-11 17:23:06 UTC done
il reste VAC1. on le fera au petit matin.
Date: 2013-10-11 16:24:56 UTC VAC3:
Starting the upgrade/download of following FPD:
=========== ==== ======= ======= =========== =========
Current Upg/Dng
Location Type Subtype Upg/Dng Version Version
=========== ==== ======= ======= =========== =========
0/0/CPU0 lc fpga2 upg 1.17 1.18
------------------------------------------------------
FPD upgrade in progress. Max timeout remaining 89 min.
FPD upgrade in progress. Max timeout remaining 88 min.
FPD upgrade in progress. Max timeout remaining 87 min.
Successfully upgraded fpga2 for ASR9001-LC on location 0/0/CPU0 from 1.17 to 1.18
FPD upgrade has ended.
RP/0/RSP0/CPU0:vac3-0-a9(admin)#
RP/0/RSP0/CPU0:vac3-0-a9#hw-module location 0/0/CPU0 reload
Fri Oct 11 18:27:27.734 CEST
WARNING: This will take the requested node out of service.
Do you wish to continue?[confirm(y/n)]y