paris/madrid
Incident Report for Network & Infrastructure
Resolved
L'un des 10G que nous avons entre Paris et Madrid est tombé.
Après les recherches, il se trouve que la puissance optique
en reception est trop fiable.

gsw-2-6k#sh inter ten 8/3 transceiver
Transceiver monitoring is disabled for all interfaces.

ITU Channel not available (Wavelength not available),
Transceiver is internally calibrated.
If device is externally calibrated, only calibrated values are printed.
++ : high alarm, + : high warning, - : low warning, -- : low alarm.
NA or N/A: not applicable, Tx: transmit, Rx: receive.
mA: milliamperes, dBm: decibels (milliwatts).

Optical Optical
Temperature Voltage Current Tx Power Rx Power
Port (Celsius) (Volts) (mA) (dBm) (dBm)
------- ----------- ------- -------- -------- --------
Te8/3 35.0 0.00 55.5 -2.2 -12.4

On recoupe le lien et on va regarder pour trouver l'origine du
probleme: soit une contraite sur une fibre optique soit l'optique
en face trop fiable.

Update(s):

Date: 2010-08-01 08:09:30 UTC
Les travaux ont été terminés. Le lien est à nouveau up.

Date: 2010-07-31 22:38:04 UTC
Le trafic s'ecoule vie le 2ème lien 2x10G que nous
avons en place. Il n'y a donc pas de degradation du
service.

Date: 2010-07-31 22:37:35 UTC
Le 2ème lien vient de tomber.

Les équipements en face ne nous envoit plus de lumieres.
Il s'agit là des travaux en cours en Espagne.

gsw-2-6k#sh inter ten 8/3 transceiver
Transceiver monitoring is disabled for all interfaces.

ITU Channel not available (Wavelength not available),
Transceiver is internally calibrated.
If device is externally calibrated, only calibrated values are printed.
++ : high alarm, + : high warning, - : low warning, -- : low alarm.
NA or N/A: not applicable, Tx: transmit, Rx: receive.
mA: milliamperes, dBm: decibels (milliwatts).

Optical Optical
Temperature Voltage Current Tx Power Rx Power
Port (Celsius) (Volts) (mA) (dBm) (dBm)
------- ----------- ------- -------- -------- --------
Te8/3 35.4 0.00 55.3 -2.1 -40.0

gsw-2-6k#sh inter ten 2/1 transceiver
Transceiver monitoring is disabled for all interfaces.

ITU Channel not available (Wavelength not available),
Transceiver is internally calibrated.
If device is externally calibrated, only calibrated values are printed.
++ : high alarm, + : high warning, - : low warning, -- : low alarm.
NA or N/A: not applicable, Tx: transmit, Rx: receive.
mA: milliamperes, dBm: decibels (milliwatts).

Optical Optical
Temperature Voltage Current Tx Power Rx Power
Port (Celsius) (Volts) (mA) (dBm) (dBm)
------- ----------- ------- -------- -------- --------
Te2/1 36.2 0.00 32.5 -1.6 -34.0 --

gsw-2-6k#
Posted Jul 31, 2010 - 09:56 UTC